Violation Detail
Standard Cited: 19260452 A04 Additional requirements applicable to specific types of scaffolds.
Inspection Nr: 1295207.015
Citation: 01004B
Citation Type: Serious
Abatement Date: 08/14/2018 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/08/2018
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): A;I
Gravity: 10
Report ID: 0215000
Contest Date: 08/31/2018
Final Order: 01/30/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 01/30/2019 | $0.00 | 08/14/2018 | Serious | |
Penalty | C: Contested | 09/05/2018 | $0.00 | 08/14/2018 | Serious | |
Penalty | Z: Issued | 08/08/2018 | $0.00 | 08/14/2018 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1926.452(a)(4): Diagonal bracing in both directions was not installed across the entire outside face of all double- and single-pole scaffolds. a) Courtyard at the end of building abutting the next door building: On or about February 13, 2018 The diagonal bracing was not installed on the job made multi-story wood pole scaffold.