Violation Detail
Standard Cited: 19100217 C01 I Mechanical power presses.
Inspection Nr: 1117151.015
Citation: 01005
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $2,618.00
Current Penalty: $1,400.00
Issuance Date: 03/21/2016
Nr Instances: 2
Nr Exposed: 20
Related Event Code (REC):
Gravity: 5
Report ID: 0419700
Contest Date:
Final Order: 04/15/2016
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/15/2016 | $1,400.00 | Serious | ||
Penalty | Z: Issued | 03/21/2016 | $2,618.00 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.217(c)(1)(i): The employer did not provide and insure the usage of "point of operation guards" or properly applied and adjusted point of operation devices on every operation performed on a mechanical power press: a. On January 12, 2016, in department 1, the Cincinnati power press wire chopper does not have an adequate guard at the point of operation, exposing employees to an amputation hazard. b. On January 12, 2016, in department 2, the Alamo power press wire chopper does not have an adequate guard at the point of operation, exposing employees to an amputation hazard.