Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1309182.015
Citation: 01005
Citation Type: Serious
Abatement Date: 10/12/2018 2
Initial Penalty: $3,880.00
Current Penalty: $2,500.00
Issuance Date: 09/19/2018
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 1
Report ID: 0419400
Contest Date:
Final Order: 10/16/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/16/2018 | $2,500.00 | 10/12/2018 | Serious | |
Penalty | Z: Issued | 09/19/2018 | $3,880.00 | 10/12/2018 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.219(c)(4)(i): Shaft ends projecting more than one-half the diameter of the shaft were not guarded by nonrotating caps or safety sleeves. (a) Exterior Main Wall Line - On or about April 19, 2018 a 2 inch shaft end projected more than 2 inches.