Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1383066.015
Citation: 01005
Citation Type: Other
Abatement Date: 09/24/2019 2
Initial Penalty: $11,934.00
Current Penalty: $11,934.00
Issuance Date: 08/30/2019
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 10
Report ID: 0627510
Contest Date: 09/24/2019
Final Order: 08/08/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 08/08/2022 | $11,934.00 | 09/24/2019 | Other | |
Penalty | C: Contested | 09/25/2019 | $11,934.00 | 09/24/2019 | Serious | |
Penalty | Z: Issued | 08/30/2019 | $11,934.00 | 09/24/2019 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section On or about March 4, 2019, and at times prior thereto, at the tank battery train #7, employees performed maintenance and/or repairs to a level controller/float on the heater treater oil boot and peanut valve. The employer did not develop or document specific procedures for this equipment for the control of hazardous energy. Specific procedures were not provided.