Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1384550.015
Citation: 01005
Citation Type: Serious
Abatement Date: 10/02/2019 2
Initial Penalty: $13,260.00
Current Penalty: $13,260.00
Issuance Date: 09/06/2019
Nr Instances: 1
Nr Exposed: 11
Related Event Code (REC):
Gravity: 10
Report ID: 0418200
Contest Date: 09/26/2019
Final Order:
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 10/16/2019 | $13,260.00 | 10/02/2019 | Serious | |
Penalty | Z: Issued | 09/06/2019 | $13,260.00 | 10/02/2019 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Assembly Line/Clean Room - On or about 3/9/2019 and at times prior thereto, the employer exposed employees to caught-in hazards in that the employer failed to conduct periodic inspections of the energy control procedures for machinery with multiple energy sources which includes but is not limited to GA 00-100 TM Case Turn Over #1 machine.