Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 965405.015
Citation: 01005
Citation Type: Serious
Abatement Date: 01/30/2015 2
Initial Penalty: $7,000.00
Current Penalty: $5,000.00
Issuance Date: 09/22/2014
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): A
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 10/20/2014
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/20/2014 | $5,000.00 | 01/30/2015 | Serious | |
Penalty | Z: Issued | 09/22/2014 | $7,000.00 | 10/02/2014 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.147(c)(4)(ii)(B): Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; The specific energy control procedure for the AFE-6 Casemaster Atmosphere Heat Treat Furnace #21, did not identify a specific method of securing the raised pneumatically operated oil filled quench tank chamber outer metal door to prevent it from falling.