Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1354706.015
Citation: 01005A
Citation Type: Serious
Abatement Date: 02/04/2019 3
Initial Penalty: $3,880.00
Current Penalty: $2,000.00
Issuance Date: 11/23/2018
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 1
Report ID: 1032500
Contest Date:
Final Order: 12/12/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/12/2018 | $2,000.00 | 02/04/2019 | Serious | |
Penalty | Z: Issued | 11/23/2018 | $3,880.00 | Serious |
Text For Citation: 01 Item/Group: 005A Hazard:
29 CFR 1910.219(d)(1): Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, were not guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. a) On or about October 19, 2018, or prior thereto: The pulleys on a motor controlling conveyor speed on the Onion Bin Tipping Machine was not guarded. The pulley was 67 inches above ground level and located adjacent to an employee aisle way. Employees accessed this location to clean onion residue. NOTE: Abatement certification is NOT required for this item.