Violation Detail
Standard Cited: 19100179 N02 II Overhead and gantry cranes.
Inspection Nr: 1579386.015
Citation: 01005A
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $10,151.00
Current Penalty: $10,151.00
Issuance Date: 08/03/2022
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): A
Gravity: 10
Report ID: 0521100
Contest Date:
Final Order: 08/29/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/29/2022 | $10,151.00 | Serious | ||
Penalty | Z: Issued | 08/03/2022 | $10,151.00 | Serious |
Text For Citation: 01 Item/Group: 005A Hazard:
29 CFR 1910.179(n)(2)(ii): The load shall be attached to the load block hook by means of slings or other approved devices. On or about February 15, 2022, with respect to an establishment located at 1101 Perry St, Algoma, WI 54201, the employer failed to ensure approved lifting devices were utilized. A locally manufactured spreader bar was being used to lift a 740-pound Penthouse Skid.