Violation Detail
Standard Cited: 19261431 J01
Inspection Nr: 1520787.015
Citation: 01005B
Citation Type: Other
Abatement Date: 09/30/2021 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/16/2021
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 10
Report ID: 0626700
Contest Date: 10/05/2021
Final Order: 03/08/2023
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 03/08/2023 | $0.00 | 09/30/2021 | Other | |
Penalty | C: Contested | 10/07/2021 | $0.00 | 09/30/2021 | Serious | |
Penalty | Z: Issued | 09/16/2021 | $0.00 | 09/30/2021 | Serious |
Text For Citation: 01 Item/Group: 005B Hazard:
29 CFR 1926.1431(j)(1): Prior to hoisting employees on the personnel platform, and after any repair or modification, the platform and rigging was not proof tested to 125 percent of the platform's rated capacity: a) On or about March 21, 2021, at the jobsite, the proof test of the personnel platform was not tested to 125 percent of the platform's rated capacity prior to hoisting employees tasked with attaching the arms of a power line monopole.