Violation Detail
Standard Cited: 19101025 J02 I Lead.
Inspection Nr: 1661174.015
Citation: 01006B
Citation Type: Serious
Abatement Date: 10/03/2023 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/18/2023
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): C
Gravity: 10
Report ID: 0214200
Contest Date:
Final Order: 09/11/2023
Emphasis:
Substance: 1591
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/11/2023 | $0.00 | 10/03/2023 | Serious | |
Penalty | Z: Issued | 08/18/2023 | $0.00 | 10/03/2023 | Serious |
Text For Citation: 01 Item/Group: 006B Hazard:
29 CFR 1910.1025(j)(2)(i):The employer did not make available biological monitoring, including blood sampling and analysis for lead and zinc protoporphyrin levels for each employee covered under 29 CFR 1910.1025 (j)(1)(i): Location: Mirion Technologies (Capintec), Inc., 7 Vreeland Road, Florham Park, NJ a) The employer did not provide blood sampling and analysis for employees that were exposed to levels of lead at or above the action level. On May 8, 2023, an employee sanding shielding materials in the machine room was exposed to respirable lead concentrations of 120 micrograms per cubic meter of air as an 8 hour Time Weighted Average exceeding the Permissible Exposure Limit (PEL) of 50 micrograms per cubic meter of air by 2.4 times. Zero exposure was assumed for the unsampled period of 66 minutes. The shielding material used contained 99.99 percent lead. Violation occurred on or about May 8, 2023.