Violation Detail
Standard Cited: 19100146 D06 Permit-required confined spaces
Inspection Nr: 1582106.015
Citation: 01008
Citation Type: Serious
Abatement Date: 10/13/2022 2
Initial Penalty: $10,151.00
Current Penalty: $15,625.00
Issuance Date: 09/06/2022
Nr Instances: 2
Nr Exposed: 2
Related Event Code (REC): A
Gravity: 10
Report ID: 0521400
Contest Date: 09/20/2022
Final Order: 06/20/2023
Emphasis:
Substance: 0640
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 06/20/2023 | $15,625.00 | 10/13/2022 | Serious | |
Penalty | C: Contested | 09/22/2022 | $10,151.00 | 10/13/2022 | Serious | |
Penalty | Z: Issued | 09/06/2022 | $10,151.00 | 10/13/2022 | Serious |
Text For Citation: 01 Item/Group: 008 Hazard:
29 CFR 1910.146(d)(6):Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not provide at least one attendant outside the permit space into which entry was authorized for the duration of entry operations: Bay 6: On or about March 7, 2022, employees at B & R Repair, Inc were required to complete the visual internal inspection portion of the annual DOT certification inside a permit required confined space, a rubber-lined semi tanker trailer containing a sodium hypochlorite solution. The employer did not provide at least one attendant outside the permit space into which entry was authorized for the duration of entry operations. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(c).