Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1695679.015
Citation: 01009
Citation Type: Serious
Abatement Date: 04/03/2024
Initial Penalty: $12,421.00
Current Penalty: $12,421.00
Issuance Date: 02/28/2024
Nr Instances: 2
Nr Exposed: 1
Related Event Code (REC): C
Gravity: 10
Report ID: 0521100
Contest Date: 03/21/2024
Final Order:
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 03/22/2024 | $12,421.00 | 04/03/2024 | Serious | |
Penalty | Z: Issued | 02/28/2024 | $12,421.00 | 04/03/2024 | Serious |
Text For Citation: 01 Item/Group: 009 Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6). At an establishment located at 5215 Mill Road in Laona, Wisconsin; in Plant B, the employer did not ensure that all the steps outlined in 29 CFR 1910.147(d), required for the control of hazardous energy sources, were performed. Employees did not utilize energy control procedures when engaged in servicing and maintenance tasks in Plant B of the facility. (a) On or about September 12, 2023, employees were exposed to machine hazards associated with moving parts when they engaged in changing the side profile cutting head on the LMC Leadermac Speed Mac 523. The employer did not ensure that employees implemented energy control application steps prior to allowing them to set up. The machine was not deenergized at an energy isolating device prior to the employee engaging in the set-up activity. (b) On or about September 12, 2023, employees were exposed to machine hazards associated with moving parts when they engaged in troubleshooting an air leak on the LMC Leadermac Speed Mac 523. The employer did not ensure that employees implemented energy control application steps prior to allowing them to troubleshoot. The machine was not deenergized at an energy isolating device prior to the employee engaging in troubleshooting activities. As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.