Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1214047.015
Citation: 01010
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $12,675.00
Current Penalty: $7,603.54
Issuance Date: 08/31/2017
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): A;R
Gravity: 10
Report ID: 0214500
Contest Date: 09/25/2017
Final Order: 04/09/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 05/02/2018 | $12,675.00 | Serious | ||
Penalty | F: Formal Settlement | 04/09/2018 | $7,603.54 | Serious | ||
Penalty | Z: Issued | 08/31/2017 | $12,675.00 | Serious |
Text For Citation: 01 Item/Group: 010 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Concrete Mixing Drum: The employer did not conduct a periodic inspection of the company energy control procedures at least annually to ensure that the procedure and the requirements of this standard are being followed, on or about 03/01/2017.