Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1367898.015
Citation: 01011
Citation Type: Serious
Abatement Date: 07/10/2019 2
Initial Penalty: $9,282.00
Current Penalty: $5,900.00
Issuance Date: 06/18/2019
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 10
Report ID: 0521400
Contest Date:
Final Order: 07/09/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/09/2019 | $5,900.00 | 07/10/2019 | Serious | |
Penalty | Z: Issued | 06/18/2019 | $9,282.00 | 07/10/2019 | Serious |
Text For Citation: 01 Item/Group: 011 Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: On or about December 20 and 21, 2018, employees were required to clean out the line 2 quench tank. This task required employees to perform lockout/tagout to safely perform their duties. The employer did not provide training to the employees on the energy control program and the employees did not lockout the equipment. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).