Violation Detail
Standard Cited: 19100146 K03 Permit-required confined spaces
Inspection Nr: 1199680.015
Citation: 01012A
Citation Type: Serious
Abatement Date: 02/02/2018 2
Initial Penalty: $6,338.00
Current Penalty: $3,042.00
Issuance Date: 06/26/2017
Nr Instances: 1
Nr Exposed: 7
Related Event Code (REC):
Gravity: 5
Report ID: 0215800
Contest Date: 07/09/2017
Final Order: 02/02/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 02/02/2018 | $3,042.00 | 02/02/2018 | Serious | |
Penalty | C: Contested | 07/26/2017 | $6,338.00 | 07/05/2017 | Serious | |
Penalty | Z: Issued | 06/26/2017 | $6,338.00 | 07/05/2017 | Serious |
Text For Citation: 01 Item/Group: 012A Hazard:
29 CFR 1910.146(k)(3): Whenever an authorized entrant entered a permit space, retrieval systems or methods were not used to facilitated non-entry rescue: a) Carthage Specialty Paperboard, Inc., on or about 1/10/17: Employees entered permit required confined spaces including but not limited to: Filler Machine Chest; Back Liner Machine Chest; Clear Cloudy Water Chest; Collection Pit; Cement Chest and was not utilizing a retrieval system, including a harness, an attached retrieval line and winch.