Violation Detail
Standard Cited: 19261101 K09 I Asbestos
Inspection Nr: 1001669.015
Citation: 01012B
Citation Type: Serious
Abatement Date: 02/18/2015 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/05/2015
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 10
Report ID: 0214200
Contest Date: 03/09/2015
Final Order: 08/03/2015
Emphasis:
Substance: 9933
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 08/03/2015 | $0.00 | 02/18/2015 | Serious | |
Penalty | C: Contested | 03/13/2015 | $0.00 | 02/18/2015 | Serious | |
Penalty | Z: Issued | 02/05/2015 | $0.00 | 02/18/2015 | Serious |
Text For Citation: 01 Item/Group: 012B Hazard:
29 CFR 1926.1101(k)(9)(i): The employer did not institute, at no cost to employees, a training program for each employee who was likely to be exposed in excess of the permissible exposure limit (PEL) and for each employee who performed Class I through IV asbestos operations: a) 168 Elizabeth Ave. Newark, NJ -3rd floor The employer did not provide Class I operation training for employees performing dry removal of approximately 80 linear feet of thermal systems insulation (TSI) from overhead piping. The insulation was found to contain up to 80% Chrysotile asbestos. Condition occurred on or about 9/24/2014