Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1367898.015
Citation: 01013
Citation Type: Serious
Abatement Date: 07/10/2019 2
Initial Penalty: $9,282.00
Current Penalty: $5,900.00
Issuance Date: 06/18/2019
Nr Instances: 2
Nr Exposed: 4
Related Event Code (REC):
Gravity: 10
Report ID: 0521400
Contest Date:
Final Order: 07/09/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/09/2019 | $5,900.00 | 07/10/2019 | Serious | |
Penalty | Z: Issued | 06/18/2019 | $9,282.00 | 07/10/2019 | Serious |
Text For Citation: 01 Item/Group: 013 Hazard:
29 CFR 1910.219(d)(1): Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, were not guarded in accordance with the standards of this section: a) On or about December 27, 2018, the employer did not provide guards of v-belt drives on the agitator drive shaft on line 2 adjacent to the east storage area. This condition presented a caught-in hazard that could result in an amputation to employees. b) On or about December 27, 2018, the employer did not provide guards of v-belt drives on the tumbler adjacent to the aisle leading to the northeast exit. This condition presented a caught-in hazard that could result in an amputation to employees. Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).