Violation Detail
Standard Cited: 19100265 E05 II A Sawmills.
Inspection Nr: 961178.015
Citation: 01014A
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $2,640.00
Current Penalty: $1,320.00
Issuance Date: 09/03/2014
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0316400
Contest Date:
Final Order: 09/25/2014
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/25/2014 | $1,320.00 | Serious | ||
Penalty | Z: Issued | 09/03/2014 | $2,640.00 | Serious |
Text For Citation: 01 Item/Group: 014A Hazard:
29 CFR 1910.265(e)(5)(ii)(a): The top(s) and opening(s) in end and side frame(s) of edger(s) were not adequately guarded: (a) Sawmill: A 2 1/2 inch x 39 1/2 inch opening on the front of the Edminstons, HE 276 edger, was not fully guarded/enclosed, as observed on March 5, 2014.