Violation Detail
Standard Cited: 19100219 B02 Mechanical power-transmission apparatus.
Inspection Nr: 1058109.015
Citation: 01015
Citation Type: Serious
Abatement Date: 10/19/2015 2
Initial Penalty: $3,300.00
Current Penalty: $1,980.00
Issuance Date: 10/08/2015
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 1
Report ID: 0111100
Contest Date:
Final Order: 11/02/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/02/2015 | $1,980.00 | 10/19/2015 | Serious | |
Penalty | Z: Issued | 10/08/2015 | $3,300.00 | 10/19/2015 | Serious |
Text For Citation: 01 Item/Group: 015 Hazard:
29 CFR 1910.219(b)(2): Crank(s) or connecting rod(s) exposed to contact were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o) or by guardrail(s): #7 Filter Room - The oscillating shower drive and connecting rod were not guarded.