Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1356616.015
Citation: 01016
Citation Type: Serious
Abatement Date: 05/13/2019 2
Initial Penalty: $9,472.00
Current Penalty: $9,472.00
Issuance Date: 04/17/2019
Nr Instances: 2
Nr Exposed: 5
Related Event Code (REC):
Gravity: 5
Report ID: 0830100
Contest Date:
Final Order: 05/14/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/14/2019 | $9,472.00 | 05/13/2019 | Serious | |
Penalty | Z: Issued | 04/17/2019 | $9,472.00 | 05/13/2019 | Serious |
Text For Citation: 01 Item/Group: 016 Hazard:
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: a) Waybridge Conveyor: On or about October 29, 2018 and at times prior, employees were exposed to caught in hazards while walking and working around the unguarded shaft end. The shaft was approximately 2 inches in diameter and the exposed portion of the shaft projected approximately 3.5 inches. b) Waybridge Conveyor: On or about October 29, 2018 and at times prior, employees were exposed to caught in hazards while walking and working around the unguarded shaft end. The shaft was approximately 2 inches in diameter and the exposed portion of the shaft projected approximately 2.5 inches.