Violation Detail
Standard Cited: 19100212 A05 General requirements for all machines.
Inspection Nr: 1207843.015
Citation: 01025
Citation Type: Serious
Abatement Date: 04/03/2018 2
Initial Penalty: $5,070.00
Current Penalty: $2,433.00
Issuance Date: 06/26/2017
Nr Instances: 1
Nr Exposed: 12
Related Event Code (REC):
Gravity: 5
Report ID: 0215800
Contest Date: 07/09/2017
Final Order: 02/02/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 02/02/2018 | $2,433.00 | 04/03/2018 | Serious | |
Penalty | C: Contested | 07/26/2017 | $5,070.00 | 07/07/2017 | Serious | |
Penalty | Z: Issued | 06/26/2017 | $5,070.00 | 07/07/2017 | Serious |
Text For Citation: 01 Item/Group: 025 Hazard:
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch: a) On or about 2/1/2017, Machine room: A fan for a heater located in the dry end break room had a 4 inch by 4.5 inch opening, exposing a fan blade. Abatement certification is required for these items.