Violation Detail
Standard Cited: 19100022 A02 General requirements.
Inspection Nr: 1058109.015
Citation: 02001
Citation Type: Repeat
Abatement Date: 10/19/2015 2
Initial Penalty: $16,500.00
Current Penalty: $9,900.00
Issuance Date: 10/08/2015
Nr Instances: 14
Nr Exposed: 35
Related Event Code (REC):
Gravity: 1
Report ID: 0111100
Contest Date:
Final Order: 11/02/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/02/2015 | $9,900.00 | 10/19/2015 | Repeat | |
Penalty | Z: Issued | 10/08/2015 | $16,500.00 | 10/19/2015 | Repeat |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition. Where wet processes were used, drainage was not maintained: Floors were not maintained in a clean and dry condition in the following instances: a) Hydro Pulper Area - Hydraulic fluid, from the Black-Clawson Guillotine pump, was leaking on the floor. b) Shipping Pulper Pit - The entire floor area was flooded. c) #1 Super Calendar - The basement floor was covered in oil. d) C2 Basement - The ramp and floor were wet from a leaking river water line. e) #1 Raw Stock Filter - The floor was covered with stock. f) #3 Raw Stock Thickener - The packing seal was leaking water from the platform down to the lower level. g) #7 Paper Machine, Drive Side Basement, P748 - Water was flowing across the walkway. h) #4 Broke Chest - The basement walkway was covered with stock and water. i) #3 Broke Chest - The basement walkway was covered with stock and water. j) Steam Plant, Condensate Water Polisher Tank Area - The aisles were wet due to a leaking roof. k) Box Shop - Hydraulic oil was leaking down from the floor above onto the shop floor. l) Next to P817 - A corroded section of metal drain pipe leaked water onto the floor. m) #7 PM WE basement - The #7 Blend Chest water was leaking down through the electrical cable trays onto the floor. n) #2 Hydropulper - The wet stock was causing the welds to rust, particularly to the confined space rescue structure. Twin Rivers Paper Company was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 314427105, Citation 1, Item 1 and was affirmed as a final order on 11/30/2010, with respect to a workplace located at 82 Bridge Avenue, Madawaska, Maine.