Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 824881.015
Citation: 02001
Citation Type: Repeat
Abatement Date: 05/08/2013 2
Initial Penalty: $7,700.00
Current Penalty: $3,850.00
Issuance Date: 04/26/2013
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0418600
Contest Date:
Final Order: 05/15/2013
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/15/2013 | $3,850.00 | 05/08/2013 | Repeat | |
Penalty | Z: Issued | 04/26/2013 | $7,700.00 | 05/08/2013 | Repeat |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) Lambda Line Spring Seat: On or about January 10, 2013: the employer exposed his employee(s) to struck-by/caught-in hazards in that he allowed his authorized employee(s) to service/replenish welding wire for the robotic welder without first locking it out to prevent accidental startup of the machine. The Daeil USA Corporation was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(d)(4)(i), which was contained in OSHA inspection number 581398 citation number 1, item number 2 and was affirmed as a final order on November 26, 2012, with respect to a workplace located at 3905 45th St. SW, Lanett, AL 36863.