Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1641623.015
Citation: 02004
Citation Type: Serious
Abatement Date: 06/09/2023 2
Initial Penalty: $4,218.00
Current Penalty: $4,218.00
Issuance Date: 05/15/2023
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 1
Report ID: 0418300
Contest Date:
Final Order: 06/08/2023
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 05/15/2023 | $4,218.00 | 06/09/2023 | Serious |
Text For Citation: 02 Item/Group: 004 Hazard:
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: (a) On or about January 9, 2023 - Assembly, employees were exposed to struck-by hazards when the rotating shaft under the sausage conveyor projected more than one-half the diameter of the shaft.