Violation Detail
Standard Cited: 19100303 F02 General.
Inspection Nr: 1058109.015
Citation: 02007
Citation Type: Repeat
Abatement Date: 10/28/2015 2
Initial Penalty: $27,500.00
Current Penalty: $16,500.00
Issuance Date: 10/08/2015
Nr Instances: 16
Nr Exposed: 15
Related Event Code (REC):
Gravity: 5
Report ID: 0111100
Contest Date:
Final Order: 11/02/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/02/2015 | $16,500.00 | 10/28/2015 | Repeat | |
Penalty | Z: Issued | 10/08/2015 | $27,500.00 | 10/28/2015 | Repeat |
Text For Citation: 02 Item/Group: 007 Hazard:
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: Disconnecting means and overcurrent devices were not legibly marked in the following instances: a) Catalog Beater Room, #6 MC Wet End Lighting Panel - Circuit breakers 1, 3, 30, 34, 35, and 36 were not legibly marked. b) #8 Dry End Office, Panel - Double pole circuit breakers 6, 8 and 24, 26 were not identified c) New Train Shed, Lighting Panel #1 - Double pole circuit breakers 1 & 3 and 5 & 7 were inadequately labeled. d) Hydropulper Substation, Hydra #2 LP Panel - Circuit breakers 7, 9, 11, 13, 15, 25, 31, 41, 12, 14, 20, 22, 24, 26, 28, 30, 32, 34, 36, 38, and 40 were not labeled e) Hydropulper Substation, Hydra #2 PP Panel - Circuit breakers 33, 35, 37, 39, 41, 28, 30, 32, 34, 36, 38, and 40 were not labeled. f) Hydropulper Substation, Lighting Panel #1 - Circuit breakers 11, 23, 25 and 10 were not labeled g) Pipe Shop, Lighting Panel - Circuit breaker 14 was in the "On" position and was not labeled. h) Pipe Shop Area, Lighting Panel - Circuit breakers 15, 17, 19, 2, and 4 were not labeled. i) Box Shop, Lighting Panel - Circuit breaker 29 was not labeled. j) Bond Garage, Power Panel - Double pole circuit breaker 27 and 29 was not labeled. k) Receiving Basement, Subpanel LP #4 - Double pole circuit breakers 13, 15 and 14, 16 were incorrectly labeled. l) #5 Paper Machine Drive Substation, #5 MC Drive Sub Lighting Panel - Circuit breakers 22, 24, 26, and 39 were not labeled. m) Westinghouse Substation, Lighting Distribution Panel 25 KVA - Circuit breakers 32 and 34 were not labeled. n) Butler Building, Lighting Panel #3 - Circuit breakers 27, 29, 31, 32, and 33 were not labeled. o) Sand Filter Room, Lighting Panel - Circuit breakers 1,2,3, and 4 were not labeled. p) Clay Storage Area, Train Shed Lighting Panel - Circuit breakers 7, 19-37, 39, and 41 were not labeled. Twin Rivers Paper Company was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 314427105, Citation 1, Item 15 and was affirmed as a final order on 11/30/2010, with respect to a workplace located at 82 Bridge Avenue, Madawaska, Maine.