Violation Detail
Standard Cited: 19150053 D01 Welding, cutting and heating in way of preservative coatings.
Inspection Nr: 1125468.015
Citation: 02010C
Citation Type: Willful
Abatement Date: 02/02/2017 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/29/2016
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 10
Report ID: 0523900
Contest Date: 08/17/2016
Final Order: 01/03/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 01/03/2017 | $0.00 | 02/02/2017 | Willful | |
Penalty | C: Contested | 08/17/2016 | $0.00 | 08/26/2016 | Willful | |
Penalty | Z: Issued | 07/29/2016 | $0.00 | 08/26/2016 | Willful |
Text For Citation: 02 Item/Group: 010C Hazard:
29 CFR 1915.53(d)(1): In enclosed spaces, where surfaces covered with toxic preservatives were not stripped of all toxic coatings for a distance of at least 4 inches from the area of heat application, employees were not protected by air line respirators meeting the requirements of � 1915.154: (a) Herbert C. Jackson; Surfaces were not stripped of all toxic preservative coatings for a distance of at least 4 inches before hot work was performed, nor were employees required to wear air line respirators. An employee was overexposed to lead on February 11, 2016 (exposure to lead at a 10-hour TWA of 103.7 ug/m3 of air, approximately 2.60 times the permissible exposure limit of 40 ug/m3) while welding in the shell plate area.