Violation Detail
Standard Cited: 5A0001 OSH Act General Duty Paragraph
Inspection Nr: 122375512
Citation: 02048
Citation Type: Willful
Abatement Date: 08/17/1996 X
Initial Penalty: $40,000.00
Current Penalty: $20,800.00
Issuance Date: 07/12/1996
Nr Instances: 10
Nr Exposed: 6
Related Event Code (REC):
Gravity: 03
Report ID: 0112900
Contest Date: 07/23/1996
Final Order: 08/18/1997
Emphasis: X
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 08/18/1997 | $20,800.00 | 08/17/1996 | Willful | |
Penalty | Z: Issued | 07/12/1996 | $40,000.00 | 08/17/1996 | Willful |
Text For Citation: 02 Item/Group: 048 Hazard: ELECTRIC
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees housed in trailer #15 were exposed to the hazards of fire, smoke inhalation, electric shock and electrocution: a)South Entrance - The one-bulb outside light fixture was not secured to the mounting bracket exposing live conductors to accidental contact. b)Kitchen - The three-bulb light fixture was not secured to the mounting bracket and was not provided with strain relief. c)Hall - The one-bulb light fixture did not contain a permanent and continuous path to ground. d)Kitchen - The two-bulb light fixture contained exposed live electrical conductors and was not provided with a permanent and continuous path to ground. e)Bathroom - The two-bulb light fixture contained exposed live electrical conductors and was not provided with a permanent and continuous path to ground. f)Middle Bedroom - The two-bulb light fixture was not provided with a permanent and continuous path to ground. g)East Bedroom - The two-bulb light fixture was not secured to the mounting bracket and was not provided with strain relief. h)West Bedroom - The electrical outlet was not provided with a cover exposing live electrical parts to accidental contact. i)West Bedroom - The #5 fused electrical circuit was not provided with over- current protection. A screw was utilized, in place of a fuse, to complete the circuit. j)West Bedroom - The #8 fused electrical circuit was not provided with over- current protection. Tin foil was utilized, in place of a fuse, to complete the circuit. Among other methods, one feasible means of abatement would be to provide electrical installations which are in compliance with the National Electrical Code.