Accident Report Detail
Accident Summary Nr: 202510079 - Surveyor's Helper Is Run over by Scraper and Killed
Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
---|---|---|---|---|
316818749 | 09/20/2013 | 1799 | 238190 | Campanella Corporation |
Abstract: At approximately 12:12 p.m. on September 20, 2013, Employee #1, a surveyor's helper employed by a construction contractor, was conducting surveying operations at a site being prepared for residential housing construction. Coworker #1 was operating a Caterpillar 627E Twin Engine Scraper, moving it in continuous circles to level the ground for a site pad. Employee #1 was crouched on the ground at the perimeter of the scraper's drive path, placing stakes while conducting his surveying assignment. The scraper struck and ran over Employee #1. Emergency services were called, and Employee #1 was pronounced dead onsite.
End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
---|---|---|---|---|---|---|---|
Single family or duplex dwelling | New project or new addition | $20,000,000 and over | 1 | 10 | X |
Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
---|---|---|---|---|---|---|---|
1 | 316818749 | Fatality | Other | Helpers, surveyor | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Excavation Fatality Cause: Crushed/run-over of non-operator by operating cons |