Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 985179.015
Citation: 01001
Citation Type: Serious
Abatement Date: 10/16/2014 2
Initial Penalty: $3,500.00
Current Penalty: $2,500.00
Issuance Date: 09/26/2014
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0830500
Contest Date:
Final Order: 10/22/2014
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/22/2014 | $2,500.00 | 10/16/2014 | Serious | |
Penalty | Z: Issued | 09/26/2014 | $3,500.00 | 10/16/2014 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(3)(ii): The point of operation machine guards were not designed or constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle. (a) Polar Service Center, 4850 E 74th Ave., Commerce City, CO 80022: On or before July 24, 2014, the employer did not ensure that guarding on a Pacific hydraulic press was adequate. The wire used for guarding was not taunt and allowed the operator to reach the point of operation. Abatement Note: Abatement certification is not required for this item.