- Part Number:1926
- Part Number Title:Safety and Health Regulations for Construction
- Subpart:1926 Subpart S
- Subpart Title:Underground Construction, Caissons, Cofferdams, and Compressed Air
- Standard Number:
- Title:Compressed air.
- GPO Source:
General provisions.
Medical attendance, examination, and regulations.
Be capable of being maintained at a temperature, in use, not to exceed 90 °F. nor be less than 70 °F.; and
Identification badges shall be furnished to all employees, indicating that the wearer is a compressed air worker. A permanent record shall be kept of all identification badges issued. The badge shall give the employee's name, address of the medical lock, the telephone number of the licensed physician for the compressed air project, and contain instructions that in case of emergency of unknown or doubtful cause or illness, the wearer shall be rushed to the medical lock. The badge shall be worn at all times—off the job, as well as on the job.
Telephone and signal communication.
Signs and records.
The time of decompression shall be posted in each man lock as follows:
Time of Decompression for This Lock ___ pounds to ___ pounds in ___ minutes. ___ pounds to ___ pounds in ___ minutes. (Signed by) _________(Superintendent) This form shall be posted in the Man Lock at all times.
Compression.
Decompression.
Decompression to normal condition shall be in accordance with the Decompression Tables in appendix A of this subpart.
Man locks and special decompression chambers —
Man locks.
A clock, thermometer, and continuous recording pressure gauge with a 4-hour graph shall be installed outside of each man lock and shall be changed prior to each shift's decompression. The chart shall be of sufficient size to register a legible record of variations in pressure within the man lock and shall be visible to the lock attendant. A copy of each graph shall be submitted to the appointed physician after each shift. In addition, a pressure gauge, clock, and thermometer shall also be installed in each man lock. Additional fittings shall be provided so that test gauges may be attached whenever necessary.
Man locks shall be maintained at a minimum temperature of 70 °F.
Special decompression chamber.
Compressor plant and air supply.
Low-pressure air shall be regulated automatically. In addition, manually operated valves shall be provided for emergency conditions.
Ventilation and air quality.
The air in the workplace shall be analyzed by the employer not less than once each shift, and records of such tests shall be kept on file at the place where the work is in progress. The test results shall be within the threshold limit values specified in subpart D of this part, for hazardous gases, and within 10 percent of the lower explosive limit of flammable gases. If these limits are not met, immediate action to correct the situation shall be taken by the employer.
The temperature of all working chambers which are subjected to air pressure shall, by means of after-coolers or other suitable devices, be maintained at a temperature not to exceed 85 °F.
Electricity.
All electrical equipment and wiring for light and power circuits shall comply with the requirements of subpart K of this part for use in damp, hazardous, high temperature, and compressed air environments.
Sanitation.
Fire prevention and protection.
While welding or flame-cutting is being done in compressed air, a firewatch with a fire hose or approved extinguisher shall stand by until such operation is completed.
Fire hose shall be at least 1 1⁄2 inches in nominal diameter; the water pressure shall at all times be adequate for efficient operation of the type of nozzle used; and the water supply shall be such as to ensure an uninterrupted flow. Fire hose, when not in use, shall be located or guarded to prevent injury thereto.
Tunnels shall be provided with a 2-inch minimum diameter water line extending into the working chamber and to within 100 feet of the working face. Such line shall have hose outlets with 100 feet of fire hose attached and maintained as follows: One at the working face; one immediately inside of the bulkhead of the working chamber; and one immediately outside such bulkhead. In addition, hose outlets shall be provided at 200-foot intervals throughout the length of the tunnel, and 100 feet of fire hose shall be attached to the outlet nearest to any location where flammable material is being kept or stored or where any flame is being used.
All explosives used in connection with compressed air work shall be selected, stored, transported, and used as specified in subpart U of this part.
Bulkheads and safety screens.
In tunnels 16 feet or more in diameter, hanging walkways shall be provided from the face to the man lock as high in the tunnel as practicable, with at least 6 feet of head room. Walkways shall be constructed of noncombustible material. Standard railings shall be securely installed throughout the length of all walkways on open sides in accordance with subpart M of this part. Where walkways are ramped under safety screens, the walkway surface shall be skidproofed by cleats or by equivalent means.
[44 FR 8577, Feb. 9, 1979; 44 FR 20940, Apr. 6, 1979, as amended at 47 FR 14696, 14706, Apr. 6, 1982; 51 FR 25318, July 11, 1986; 61 FR 5507, Feb. 13, 1996]