For landside areas, the employer shall provide illumination that meets the levels set forth in Table F-1 to § 1915.82.
Lumens (foot-candles) |
Area or operation |
---|---|
3 | General areas on vessels and vessel sections such as accessways, exits, gangways, stairs, and walkways. |
5 | General landside areas such as corridors, exits, stairs, and walkways. |
5 | All assigned work areas on any vessel or vessel section. |
5 | Landside tunnels, shafts, vaults, pumping stations, and underground work areas. |
10 | Landside work areas such as machine shops, electrical equipment rooms, carpenter shops, lofts, tool rooms, warehouses, and outdoor work areas. |
10 | Changing rooms, showers, sewered toilets, and eating, drinking, and break areas. |
30 | First aid stations, infirmaries, and offices. |
NOTE TO TABLE F–1 TO §1915.82: The required illumination levels in this table do not apply to emergency or portable lights.
Explosion-proof, self-contained lights. The employer shall provide and ensure that each employee uses only explosion-proof, self-contained temporary and portable lights, approved for hazardous conditions by a nationally recognized testing laboratory (NRTL), in any area that the atmosphere is determined to contain a concentration of flammable vapors that are at or above 10 percent of the lower explosive limit (LEL) as specified in 29 CFR part 1915, subparts B and C.