Inspection Detail
Inspection: 1202377.015 - Basin Anchor Steam & Pressure Solutions Inc.
Inspection Information - Office: Lubbock Area Office
Site Address:
Basin Anchor Steam & Pressure Solutions Inc.
Phoenix Lease Services Inc. 8310 W. I-20
Midland, TX 79706
Mailing Address:
1204 E. Magnolia, Midland, TX 79705
Union Status: NonUnion
SIC:
NAICS: 213112/Support Activities for Oil and Gas Operations
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 01/12/2017
Emphasis: P:Oilgas, L:Oilgas
Case Closed: 09/16/2019
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1172838 | ||
Inspection | 1215648 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 3 | 3 | ||||
Current Violations | 3 | 3 | ||||
Initial Penalty | $38,025 | $0 | $0 | $0 | $0 | $38,025 |
Current Penalty | $38,025 | $0 | $0 | $0 | $0 | $38,025 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001A | Serious | 19100134 C01 | 07/11/2017 | 09/01/2017 | $12,675 | $12,675 | $0 | I - Informal Settlement | ||
2. | 01001B | Serious | 19100134 D01 III | 07/11/2017 | 09/01/2017 | $0 | $0 | $0 | I - Informal Settlement | ||
3. | 01001C | Serious | 19100134 E01 | 07/11/2017 | 09/01/2017 | $0 | $0 | $0 | I - Informal Settlement | ||
4. | 01001D | Serious | 19100134 F01 | 07/11/2017 | 09/01/2017 | $0 | $0 | $0 | I - Informal Settlement | ||
5. | 01002A | Serious | 19100146 C04 | 07/11/2017 | 09/01/2017 | $12,675 | $12,675 | $0 | I - Informal Settlement | ||
6. | 01002B | Serious | 19100146 G01 | 07/11/2017 | 09/01/2017 | $0 | $0 | $0 | I - Informal Settlement | ||
7. | 01003 | Serious | 19101200 E01 | 07/11/2017 | 09/01/2017 | $12,675 | $12,675 | $0 | I - Informal Settlement |
Investigation Summary
Employee was using a pressure washer to clean the inside of a 500 barrel frack tank. While cleaning the inside of the tank the employee fell unconscious and wound up submerged in the frac fluid leading to an aspiration of petroleum products. When management went to check on the employee he was found unconscious and partial submerged in the tank water.
Keywords: Confined Space, Frac Tank, Unconsciousness
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1202377.015 | 62 | M | Fatality | Janitors and cleaners |