Inspection Detail
Inspection: 1301193.015 - Southern Gardens Groves Corporation
Inspection Information - Office: Tampa Area Office
Site Address:
Southern Gardens Groves Corporation
18511 Docs Lane
Alva, FL 33920
Mailing Address:
1820 County Road 833, Clewiston, FL 33440
Union Status: NonUnion
SIC:
NAICS: 115115/Farm Labor Contractors and Crew Leaders
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/12/2018
Emphasis: L:Ohpwrlne
Case Closed: 02/13/2019
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1317333 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $12,934 | $0 | $0 | $0 | $0 | $12,934 |
Current Penalty | $11,634 | $0 | $0 | $0 | $0 | $11,634 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 5A0001 | 09/07/2018 | 09/24/2018 | $11,634 | $12,934 | $0 | I - Informal Settlement |
Investigation Summary
At 8:23 a.m. at March 11, 2018, a migrant worker was working from a 17 foot by 4 inch aluminum ladder to pick oranges. During work, the employee's ladder contacted an overhead power line that was energized at 13.4 kV. The employee was electrocuted.
Keywords: Electrocuted, Ladder, Power Lines
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1301193.015 | 34 | M | Fatality | Agriculture and forestry teachers |