Inspection Detail
Inspection: 1334092.015 - Robert Dominikus General Engineering
Inspection Information - Office: Redding District Office
Site Address:
Robert Dominikus General Engineering
Rock Creek Rd. And Benson Dr. N40*37'45" W122 29'5"
Shasta, CA 96087
Mailing Address:
P.O. Box 265, Pollock Pines, CA 95726
Union Status: NonUnion
SIC:
NAICS: 115310/Support Activities for Forestry
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/14/2018
Emphasis:
Case Closed: 03/28/2019
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1364930 | ||
Inspection | 1343100 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $0 | $0 | $0 | $435 | $0 | $435 |
Current Penalty | $0 | $0 | $0 | $435 | $0 | $435 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 3203(A) | 12/14/2018 | $435 | $435 | $0 | 01/03/2019 | O - Administrative Law Judge Order |
Investigation Summary
At 4:45 p.m. on July 26, 2018, an employee was dispatched to an active fire location. A John Deere 700H dozer (model number: TO700HX908361) was unloaded from its transport and the employee began tracking to meet with a Strike team leader for assignment. The employee was approximately 20 minutes into his shift when the fire got worse and a convergence of two fire fronts occurred as a result of shifting winds. The employee became surrounded by the fire and was killed.
Keywords: Bulldozer, Fire
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1334092.015 | 81 | M | Fatality | Equipment Operator: Heavy |