Inspection Detail
Inspection: 1517766.015 - 63554 - Tv Service Inc
Inspection Information - Office: Ky Labor Cabinet Division Of Osh Compliance
Site Address:
63554 - Tv Service Inc
37 Buttery Drive
Isom, KY 41824
Mailing Address:
Po Box 1410, Hindman, KY 41822
Union Status: NonUnion
SIC:4813
NAICS: 517110/Wired Telecommunications Carriers
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/20/2021
Emphasis:
Case Closed: 09/14/2021
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1742258 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 19100132 D02 | 08/28/2021 | 09/10/2021 | $0 | $0 | $0 | Z - Issued |
Investigation Summary
At 12:00 a.m. on March 2, 2021, Employee #1 and Employee #2 were installing new coax wiring to an existing residence. The coax wire became energized after contacting a overhead electric wire. Employee #1 was killed by electrocution. Employee #2 incurred electrical shock and was hospitalized.
Keywords: Electric Shock, Electrocuted, Installing, Overhead Power Line
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1517766.015 | 23 | M | Fatality | Occupation not reported |