Inspection Detail
Inspection: 305090144 - Silver Lake Welding Service, Inc.
Inspection Information - Office: Nc Department Of Labor - Winston-Salem
Site Address:
Silver Lake Welding Service, Inc.
10949 Highway 268
Elkin, NC 28621
Mailing Address:
2433 Silver Lake Road, Dayton, VA 22821
Union Status: NonUnion
SIC:7692
NAICS: 811310/Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/01/2002
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 10/03/2003
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 100071588 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 7 | 2 | 9 | |||
Current Violations | 3 | 2 | 5 | |||
Initial Penalty | $7,700 | $0 | $0 | $0 | $0 | $7,700 |
Current Penalty | $2,800 | $0 | $0 | $0 | $0 | $2,800 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100272 G01 II | 05/15/2002 | 05/23/2002 | $2,100 | $2,100 | $0 | 07/15/2002 | R - Review Commission | |
2. | 01002 | Serious | 19100272 G02 | 05/15/2002 | 05/23/2002 | $0 | $2,100 | $0 | 07/15/2002 | R - Review Commission | Citation has been deleted. |
3. | 01003 | Serious | 95012901 | 05/15/2002 | 07/02/2002 | $350 | $350 | $0 | 07/15/2002 | R - Review Commission | |
4. | 01004 | Serious | 19100023 C01 | 05/15/2002 | 05/23/2002 | $350 | $350 | $0 | 07/15/2002 | R - Review Commission | |
5. | 01005 | Serious | 19100146 G01 | 05/15/2002 | 05/30/2002 | $0 | $350 | $0 | 07/15/2002 | R - Review Commission | Citation has been deleted. |
6. | 01006 | Serious | 19100146 D09 | 05/15/2002 | 05/30/2002 | $0 | $350 | $0 | 07/15/2002 | R - Review Commission | Citation has been deleted. |
7. | 01007 | Serious | 19100252 A02 VIC | 05/15/2002 | 05/23/2002 | $0 | $2,100 | $0 | 07/15/2002 | R - Review Commission | Citation has been deleted. |
8. | 02001 | Other | 19100106 D02 III | 05/15/2002 | 07/02/2002 | $0 | $0 | $0 | 07/15/2002 | R - Review Commission | |
9. | 02002 | Other | 19100305 G02 III | 05/15/2002 | 07/02/2002 | $0 | $0 | $0 | 07/15/2002 | R - Review Commission |
Investigation Summary
At 10:30 a.m. on February 21, 2002, Employee #1 and Employee #2 of Silver Lake Welding Service, Incorporated were working inside feed bin number 17 repairing worn metal plating on the walls. The air actuated slide gate for bin number 17 was opened, releasing its contents of approximately 12 feet in depth grain with two employees caught in the grain. The older employee was pulled under the grain first with his legs partially exposed out the slide gate opening. The other employee also pulled under the grain was wedged in on top of the older employee, preventing the two from coming on through the slide gate opening. A truck driver called for medical assistance. The Elkin Rescue Service arrived at the accident site and found one of the employees for Silver Lake Welding Service, Incorporated using a cutting torch to make a 36-inch-square large hole opening to help free the two trapped employees. The older employee was partially removed up to his chest by the time the second Elkin Rescue Service member arrived on site. The Elkin Rescue Service, at the top of the feed mill bins, observed that the hand operated, Model 482, hoist, with PN A7332, was set in place above the entrance into feed bin Number 17. A boatswain chair and swing seat was attached by a 0.375-inch diameter metal cable to the hoist. The boatswain chair and swing seat had been lowered into feed bin Number 17. The 0.375-inch diameter metal cable for personnel live line rescue was attached around one of the metal angle iron post used to support the feed inlet pipes used to transfer feed grain. There were three electric cords running into feed bin Number 17. One cord was for a stick welder, one for an explosion-proof light, and one for a portable grinder. A vent hose was lying next to the entrance of feed bin Number 17, but not inside the bin. There were two ladders in use at the time of the accident. The metal fixed-rung ladder was hung over the entrance into the feed bin Number 17, and the fiberglass extension ladder was inside feed bin Number 17 at the time of the accident. The Elkin Rescue Service members removed the two employees from the bottom of feed bin Number 17 at the pneumatic actuated slide gate opening cut open by one of Silver Lake Welding Service employees. The pneumatic-actuated slide gate door opening after being cut was pulled back out of the way by the Elkin Rescue Service with a portable hand hoist. Due to the two employees being wedge in on top of one another it took the Emergency Services approximately 3 hours to free them. Employee #1 and Employee #2 were treated by the Emergency Medical Services and died from asphyxia before being transported to Northern Surry Hospital in Mount Airy.
Keywords: ASPHYXIATED, CONFINED SPACE, GRAIN, BURIED, GRAIN BIN
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 305090144 | Fatality | Asphyxia | Welders and cutters | ||
2 | 305090144 | Fatality | Asphyxia | Welders and cutters |