Inspection Detail
Inspection: 305353740 - Walt Disney Parks & Resorts Us Inc Dba Disneyland
Inspection Information - Office: Santa Ana District Office
Site Address:
Walt Disney Parks & Resorts Us Inc Dba Disneyland
1313 S Harbor Blvd
Anaheim, CA 92802
Mailing Address:
1313 S Harbor Blvd, Safety Services Dept, Anaheim, CA 92802
Union Status: Union
SIC:7996
NAICS: 713110/Amusement and Theme Parks
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/31/2004
Emphasis:
Case Closed: 08/31/2004
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 362473126 |
Investigation Summary
At approximately 9:00 p.m. on April 4, 2004, Employee #1 was operating a steam locomotive at the Disneyland resort. As the train approached block light Number 8, the engine lost fire to the boiler. The employee went through relighting procedures and then placed a burning wick into the fire box and opened the fuel line. Due to the position of the wick, more fuel vapor than normal entered the box before the fire lit. This caused a flash fire that came out of the firebox door and struck the employee. He suffered second-degree heat burns through his clothing on both knees and first- and second-degree flash burns on his wrist and face. He was hospitalized for 2 days with his injuries.
Keywords: BURN, KNEE, AMUSE PARK/CARNIVAL, FLAMMABLE VAPORS, EQUIPMENT OPERATOR, FIRE, LOCOMOTIVE, FACE, WRIST
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 305353740 | Hospitalized injury | Burn/Scald(Heat) | Locomotive operating occupations |