Lead: Secondary Lead Smelter eTool
Local Exhaust Ventilation Diagrams » Mechanical Drossing Tonolli Screw Drosser
Notes:
- Limited to dry drosses and large kettles
- Volume of flow = 4800 CFM
- Min. velocity of flow = 4500 FPM
- Open face velocities greater than or equal to 250 CFM